VME-1050-PTTI

VME 10 MHz Distribution Amplifier

Key Features:

  • Single-Slot 6U 32-bit VME Module.
  • 10 MHz & 1PPS Inputs
  • Ten 10MHz QMA Outputs
  • Serial Interface via Host Bus
  • Individually configurable offset and output amplitude.

Brandywine’s VME-1050-PTTI Distribution Amplifier provides ten 10MHz sine wave outputs from a single 6U x 4HP VME board.  The VME-1050-PTTI features individually configurable 1PPS offsets and 10 MHz signal amplitude via a VME host serial interface.

The 10 MHz outputs are specifically designed for tight phase tracking and matching.

Other output frequency options available upon request.

Specifications
Product Data Sheet

Physical

6U VME form factor per IEEE P1014

        Width:                                    4HP

Inputs

1PPS

        Connector:                            QMA

        Level:                                    TTL

        Impedance:                           50Ω

10 MHz

        Connector:                            QMA

        Level:                                    2.0Vp-p minimum

        Impedance:                           50Ω

Outputs

Frequency Outputs

        No. of outputs:                      10

        Connector:                            QMA

        Output:                                  Sine Wave

        Amplitude:                             Adjusted through software

        Phase variation:                    <1 degree

1PPS output

        No. of outputs:                      10

        Amplitude:                             LVDS

        Connector:                            VMEbus J2

Environmental

        Operating Temperature:        0-50 ºC

 

ibu-160i-MOCKUP-sm 

The IBU-160i is a general-purpose frequency distribution amplifier designed for use with Brandywine high precision time sources.

The IBU-160i is contained in a compact IU rack- mount chassis. The IBU accepts two sets of inputs, comprising the reference input (100 Hz – 100 KHz) and status from the source. The IBU provides automatic changeover should one of the on-line source inputs fail. Manual source select override is available on the front panel, or through the Ethernet interface.

A variety of status indicators are located on the front panel for instant visual feedback, together with manual controls for source selection.

A 10/100 base T Ethernet interface provides full control over the functionality of the system, including reference selection and output amplitude (on a per channel basis).

User control of the unit is via a built-in Web Browser with user-friendly graphical interface, or via SNMP for system applications.

Applications for the IBU-160i include test ranges, satellite control centers, shipboard time distribution, airports, rail terminals, and any system requiring highly reliable time code distribution.

Features:

  • Network Enabled Time Code Distribution Amplifier
  • Dual Time Code Inputs with Auto Failover
  • Support for Analog Time Codes between 100Hz and 100KHz
  • Programmable per channel amplitude
  • Supports SNMP v2c
  • 1U 19” rack mount
  • Redundant Hot Swappable Power Supplies

 

 

Product Specifications
Product Data Sheet
User Manual

Time Code Inputs  
Frequency Range

Analog Time Code
100 Hz – 100 KHz

Typical Time Codes IRIG A, B, E, G, NASA 36, XR3, AFNOR 
Amplitude & Impedance 0.5-10Vp-p, 600 Ω
Input Isolation  Transformer coupled
Number of Inputs 2
Connector Type BNC 
Input Selection Manual, Auto
Fault Inputs 
Number of Inputs 2
Signal Type TTL
Active Level Selectable for active high or low
Action Forces on-line changeover
Time Code Outputs 
Number of Outputs 16
Format Same as Input 100 Hz – 100 Khz
Output Level 1Vp-p  to +5Vp-p, short-circuit proof
Connector Type BNC
Output Isolation Transformer Isolated
Network Interface 
Interface Type 10/100 base T
Protocols HTTP, DHCP, SNMP V2c, IPV4
Connector RJ45
Console Port 
Interface Type RS232
Parameters 115200, N, 8, 1
Connector DB9
Display 
Display Type 16 bicolor LED
Functions Output status,  Ethernet settings
Status Output (Alarm) 
Type Dry relay form C contacts Ethernet SNMP trap
Alarm Function Summary of all input/output alarms (relay) Individual input, output, power (Ethernet)
Power 
Redundancy Dual redundant Single supply maintains complete unit
Voltage 90-240 VAC 50/60Hz (std), 18-36V DC Optional, 36-72VDC Optional
Power Consumption <15W
Environmental and Safety 
Temperature 
Operating -10 to +55ºC non condensing
Storage -40 to +85ºC
Product Safety EN60950-1: 2006 + A11-2009 +A1:2010 A12:2011 AS/NZS 60950-1:2011
EMC EN55022 Class A, EN50082-2, FCC Chapter 15 Class A
Ordering Information 
Basic Unit Includes Dual AC Power Supplies
19001001 2 input, 16 output IBU-160i
Power Options (order separately) 
19001002 Substitute 18-36 DC power for AC
19001003 Substitute 36-72 DC power for AC
   
Related Products:  
FDU-160i: 
22050001 2 i/p 10MHz, 16 output 10MHz Low Noise
FDA-160i: 
22050005 2 i/p , 16 output  1-20MHz wideband
   
The IBU-160i may be used with many of Brandywine’s precision time code sources such as the NFS220, or RTG-510 for distribution of precision time code outputs. 

alt IBU-160i Data Sheet

alt IBU-160i User Manual

 

havequick-splitter

Brandywine Communication’s Havequick/1PPS Distribution Amplifier (HQS) is a small rugged, powered Havequick/1PPS distribution module mounted in a 4” x 4” x 2.5” environmentally secure enclosure.  The HQS can provide an MTBF up to 1 million hours depending on configuration.

The HQS was developed to facilitate long cable runs of both 1PPS and Have Quick signals for ships or aircraft requiring these timing reference signals at multiple locations.  With the tested, ruggedized enclosure the HQS can be placed in difficult environments and difficult to reach places on ships and aircraft.  The unit may be configured for single ended or differential signals as required for the application (factory configured).  Various power options are also available upon request. Designed for “fit and forget” operation, the compact, reliable module provides an elegant solution for distribution of the timing references from an embedded military GPS receiver.

Product Specifications
Data Sheet
User Manual

Signal Input:

Connector Type: D38999/20WB35PN

1PPS:

Amplitude: 0-10V per ICD-GPS-060
Impedance: 50ohm

Have Quick:

Amplitude: 0-5V per ICD-GPS-060
Impedance: 2kohm

Signal Output : 

Connector Type: D38999/20WB35SN

1PPS:  

No of Outputs: 3
Amplitude: 0-10V per ICD-GPS-060
Impedance: 50ohm or low Z

Have Quick:

No of Outputs: 3
Amplitude: 0-5V per ICD-GPS-060
Impedance: 2kohm

Power Input:

Connector Type: D38999/20WA98PN

Power Option 1

145 VDC to 162 VDC or

Power Option 2

15 VDC to 36 VDC

Power Consumption:

<5 Watts.

Size:

3.94”x3.94”x2.36” w/o
3.94”x5.8”x2.36” incl. connectors

Reliability

MTBF:   >1,000,000 hours

Environmental

EMI:

MIL-STD-46, CE102, CS101, CS114, CS116, RE101, RE102, RS101, RS103

Relative Humidity:

95% relative humidity, non-condensing.

Operating Temp.:

0 to +50 ºC

Non-Operating Temp.:

-40 to +85 ºC.

Air Pressure:

up to +30,000 feet.

Fungus & Salt/Fog:

Conformally coated.

Settling Dust:

Base material coatings and surface treatments resilient to erosion.

Operational Vibration

Shipboard Type I MIL-STD-167-1A .

Transportation Vibration

MIL-STD-810F  Method 514, Procedure I Categories 4, 7, 8, and 10.

Shock: 

MIL-STD-810F [3] Method 516
20g/15ms saw tooth pulse

FDA-160i-mockup-sm

The FDA-160i is a general-purpose frequency distribution amplifier designed for use with Brandywine high precision time and frequency sources. The FDA-160i is contained in a compact IU rack-mount chassis. The FDA accepts two sets of inputs, comprising the reference frequency (typically 1-20MHz) and status from the source. The FDA provides automatic changeover should one of the on-line source inputs fail. Manual source select override is available on the front panel, or through the Ethernet interface. A variety of status indicators are located on the front panel for instant visual feedback, together with manual controls for source selection. A 10/100 base T Ethernet interface provides full control over the functionality of the system, including reference selection and output amplitude (on a per channel basis). User control of the unit is via a built-in Web Browser with user-friendly graphical interface, or via SNMP for system applications. Applications for the FDA-160i include secure communications systems, manufacturing facilities, digital television broadcasting and any system requiring highly reliable frequency outputs.

 

Features

  • Network Enabled Analog Frequency Distribution Amplifier
  • Dual Frequency Inputs with Auto Failover
  • Any Frequency from 1-20MHz
  • Programmable per channel amplitude
  • Supports SNMP V2c
  • 1U 19” rack mount
  • Redundant Hot Swap Power Supplies

 

Product Specifications
Product Data Sheet
User Manual

 

Reference Frequency Inputs:  
Connector Two rear panel BNC's
Amplitude 0.5 Vrms - 1 Vrms
Input Impedance 50 Ohms
Frequency 1 - 20 MHz
Input selection Auto, Manual
   
Fault Discrete Input:  
Number of Inputs 2
Connector DB9
Level TTL
Active Level Selectable active for high or low
Action Forces on-line changeover
   
Sine Wave Outputs:  
Number of Outputs 16
Connector BNC
Frequency (MHz) Same as input 1 - 20 MHz
Level 5dBm to +13dBm, short- circuit proof
   
SSB Phase Noise (with clean-up osc. Option)
Offset (Hz) dBc/Hz
1 -132 dBc
10 -142 dBc
100 -155 dBc
1,000 -163 dBc
10,000 -163 dBc
   
Harmonics -40 dBc
Cross-talk -80 dBc
Spurious -80 dBc
   
Physical/Environmental  
Temperature
Operating -10 to + 55°C non-condensing
Storage -40 to +85°C
Dimensions 19 inch Rack Mount, 1.73 inches high (1U)
14.5 inches deep
Weight 7.5 lb typical

 

 

alt FDA-160i Data Sheet

 

 

alt FDA-160i User Manual

 

 

 

fdu-160i-small

The FDU-160i is a high performance signal distribution amplifier designed for use with Brandywine high precision time and frequency sources.

The FDU-160i is contained in a compact IU rack-mount chassis.  The FDU accepts two sets of inputs, comprising the reference frequency (typically 10MHz) and status from the source.  The FDU provides automatic changeover should one of the on-line source inputs fail. Manual source select override is available on the front panel, or through the Ethernet interface.

A variety of status indicators are located on the front panel for instant visual feedback, together with manual controls for source selection.

A 10/100 base T Ethernet interface provides full control over the functionality of the system, including reference selection and output amplitude (on a per channel basis).

User control of the unit is via a built-in Web Browser with user-friendly graphical interface, or via SNMP v2c for system applications.

Applications for the FDU-160i include secure communications systems, satellite ground stations, digital television broadcasting and any system requiring highly reliable frequency outputs.

 

Product Specifications
Product Data Sheet
User Manual

Reference Frequency Inputs:  
Connector Two rear panel BNC's
Amplitude 0.5 Vrms - 1 Vrms
Input Impedance 50 Ohms
Frequency 10 MHz
Input selection Auto, Manual
   
Fault Discrete Input:  
Number of Inputs 2
Connector DB9
Level TTL
Active Level Selectable active for high or low
Action Forces on-line changeover
   
Sine Wave Outputs:  
Number of Outputs 16
Connector BNC
Frequency (MHz) Same as input
Level 5dBm to +13dBm, short- circuit proof
   
SSB Phase Noise (with clean-up osc. Option)
Offset (Hz) dBc/Hz
1 -132 dBc
10 -142 dBc
100 -155 dBc
1,000 -163 dBc
10,000 -163 dBc
   
Harmonics -40 dBc
Cross-talk -80 dBc
Spurious -80 dBc
   
Physical/Environmental  
Temperature
Operating -10 to + 55°C non-condensing
Storage -40 to +85°C
Dimensions 19 inch Rack Mount, 1.73 inches high (1U)
14.5 inches deep
Weight 7.5 lb typical

alt FDU-160i Data Sheet

alt FDU-160i User Manual

About Brandywine Communications

Brandywine Communications Inc. offers superior products to the time and frequency marketplace. Our mission is to provide the finest equipment coupled with excellent before and after sale service.

Find Out More...

Contact Us

Brandywine Communications
Ultra-Precision Time & Frequency

1153 Warner Ave
Tustin, CA 92780
Mail: info@brandywinecomm.com
Phone: 714.755.1050


TOP

Translate

enfrdeitptrues
Translate